The zubal phantom
Web11 Jul 2024 · The Zubal head phantom MRI database is used in this study for the geometrical construction of a 3D numerical head model [ 46 ]. This dataset comprises 128 slices, where each slice contains 256 × 256 cubical elements of voxel size 1.1 × … Web4 Mar 2024 · This work demonstrates that the remote method can be applied not only to the planar human body model but also to more sophisticated tissue structures that better resemble the actual human body. These models include a cylindrical human body model and the Zubal human phantom model. 10 10. I.
The zubal phantom
Did you know?
WebNumerical Zubal brain phantom used in the simulation study with putamen in black and caudate in dark grey. Source publication +7 Brain PET Partial-Volume Compensation … Web22 Sep 2024 · Methods: Clinical PET/CT data of oncology patients were used as the basis of the simulated variability inserting patient‐specific characteristics in the NCAT and the …
WebThe system evaluation was carried out using experimental phantom studies (NEMA IEC image quality body phantom), simulated PET studies using the Zubal phantom, and clinical studies representative of nonsmall cell lung cancer and pharyngolaryngeal squamous cell carcinoma. The proposed analysis methodology of clinical oncological PET data has ... WebThe CT-based Zubal phantom is a 3D whole-body computational model with 68 segmented organs or tissues [13] (http:// noodle. med. ale.y edu/ zubal/). The phantom is a 128 × 128 × 243 matrix with a 4 mm voxel size in all directions. The advantage of adopting the Zubal phantom is its excellent organ segmentation.
WebThe phantom has a 4D beating heart model which was derived from 4D tagged (MRI) data. The remaining organs in the torso of the phantom were designed based on the Visible … Web20 Dec 2005 · The Zubal phantom used for both external and internal studies is the ‘voxelman’, i.e. it is the original head and body torso phantom with no arms or legs …
WebThis work investigates the magnitude of lens-dose reduction possible with ROI imaging. EGSnrc Monte-Carlo calculations of lens dose were made for the Zubal head phantom as a function of gantry angulation and head shift from isocenter for both large and small FOV’s.
Web24 Mar 2024 · Synthetic Zubal phantom data We first conducted the experiment on synthetic emission Zubal thorax phantom data with known radioactivity concentration as shown in figure 1 . A dynamic PET image sequence (18 frames) was generated using the two-compartment model and the resolution for each frame was 128 by 128 pixels. fisherman soup in abujaWebThe authors have constructed a digital tumor phantom to address this need. The phantom was created using the Zubal phantom as input to the SimSET software used for PET … canadice grape wine recipeWebTo ensure the availability of ground-truth χvalues against which to test the accuracy of the QSM pipelines, a piece-wise constant Zubal numerical head phantom12was used with a matrix size of 256 × 256 × 128 voxels3and 1.5-mm isotropic voxel size and the following regions of interest (ROIs): four deep-gray matter ROIs (ie, the caudate nucleus … can a diaper rash look like pimplesWebThe purpose of this work is to obtain x-ray images of the human body using the Zubal phantom. The transport of the radiation, crossing the phantom and arriving on the … canadiate for a masters degreeWeb1 Jul 2004 · The Zubal phantom data provide a high-resolution model for the anatomy of a man whose height (175 cm) and weight (70.2 kg) corresponds well to the ICRP Reference Man [8] and its digital format made it suitable for computer-based calculations. can a diastasis recti be dangerousWeb15 Jun 2016 · Methods: Simulation of FDG-PET was conducted by applying the Zubal phantom as an attenuation map to the SimSET software package that employs Monte … can a diastolic bp be higher than a systolicWeb9 Dec 2015 · This demonstration tool utilizes a high resolution, voxel based digital brain (Zubal) phantom as the main object of study. A tumor of variable size can be defined by … fisherman soup